MC16-PAC-1-KIT

MC16-PAC-2-KIT

MC16-PAC-3-KIT

Access control kit for one door. The kit consists of metal enclosure with transformer and networked access controller.

The controlled door can be managed on both, read-in and read-out sides, by RS485 (MCT series readers), RACS CLK/DTA (PRT series readers) or Wiegand readers.
Door lock and readers are supplied from the controller’s onboard supply outputs capable to deliver respectively 0.2 A and 1.0 A.

Entire system is supplied from the mains transformer included in the kit.

  • access control kit for one door
  • read-in/read-out door control
  • MC16-PAC-1 networked access controller
  • interface to 4 RACS CLK/DTA readers (PRT series)
  • interface to 4 Wiegand readers
  • supply output 0.2 A
  • supply output 1.0 A
  • 0.3 A battery charging current
  • deep battery discharge protection
  • 18 V/40 VA transformer
  • tamper contact
  • space for 7 Ah battery
  • metal enclosure
  • dimensions (external):
    255.0 x 255.0 x 90.0 mm (height x width x thickness)

Access control kit for two doors. The kit consists of metal enclosure with power supply, networked access controller and IO expander.

The controlled doors can be managed on both, read-in and read-out side, by RS485 (MCT series readers), RACS CLK/DTA (PRT series readers) or Wiegand readers.
Each controlled door has separate 0.2 A supply output for readers and 1.0 A supply output for lock and other door equipment.

The back-up battery charging current can be set to 0.3 A, 0.6 A or 0.9 A. Entire system is supplied from the power supply included in the kit.

  • access control kit for two doors
  • read-in/read-out door control
  • MC16-PAC-2 networked access controller
  • MCX2D IO expander
  • interface to 4 RACS CLK/DTA readers (PRT series)
  • interface to 4 Wiegand readers
  • 2 supply outputs 0.2 A
  • 2 supply output 1.0 A
  • 0.3 A/0.6 A/0.9 A battery charging current
  • deep battery discharge protection
  • tamper contact
  • space for 7 Ah battery
  • metal enclosure
  • dimensions (external):
    295.0 x 285.0 x 90.0 mm (height x width x thickness)

Access control kit for three doors. The kit consists of metal enclosure with power supply, networked access controller and IO expander.

The controlled doors can be managed on both, read-in and read-out side, by RS485 (MCT series readers).

In case the RACS CLK/DTA (PRT series readers) or Wiegand readers are used, only one door can be controlled on two sides while the reaming one can be controlled on one side only.
Each controlled door has separate 0.2 A supply output for readers and 1.0 A supply output for lock and other door equipment.

The back-up battery charging current can be set to 0.3 A, 0.6 A or 0.9 A. Entire system is supplied from the power supply included in the kit.

  • access control kit for three doors
  • read-in/read-out door control
  • MC16-PAC-3 networked access controller
  • MCX4D IO expander
  • interface to 4 RACS CLK/DTA readers (PRT series)
  • interface to 4 Wiegand readers
  • 4 supply outputs 0.2 A
  • 4 supply outputs 1.0 A
  • 0.3 A/0.6 A/0.9 A battery charging current
  • deep battery discharge protection
  • tamper contact
  • space for 17 Ah battery
  • power supply 13.8 V/5 A
  • metal enclosure
  • dimensions (external):
    305.0 x 325.0 x 100.0 mm (height x width x thickness)

MC16-PAC-4-KIT

MCX402-1-KIT

MCX402-2-KIT

Access control kit for four doors. The kit consists of metal enclosure with power supply, networked access controller and IO expander.

The controlled doors can be managed on both, read-in and read-out side, by RS485 (MCT series readers).

In case the RACS CLK/DTA (PRT series readers) or Wiegand readers are used, doors can be controlled on read-in side only.
Each controlled door has separate 0.2 A supply output for readers and 1.0 A supply output for lock and other door equipment.

The back-up battery charging current can be set to 0.3 A, 0.6 A or 0.9 A. Entire system is supplied from the power supply included in the kit.

  • access control kit for four doors
  • read-in/read-out door control
  • MC16-PAC-4 networked access controller
  • MCX4D IO expander
  • interface to 4 RACS CLK/DTA readers (PRT series)
  • interface to 4 Wiegand readers
  • 4 supply outputs 0.2 A
  • 4 supply outputs 1.0 A
  • 0.3 A/0.6 A/0.9 A battery charging current
  • deep battery discharge protection
  • tamper contact
  • space for 17 Ah battery
  • power supply 13.8 V/5 A
  • metal enclosure
  • dimensions (external):
    305.0 x 325.0 x 100.0 mm (height x width x thickness)

Door expander kit for one door. The kit consists of metal enclosure with transformer and IO expander.

The controlled doors can be managed on both, read-in and read-out side, by RACS CLK/DTA (PRT series readers) or Wiegand readers.

Door lock and readers are supplied from the controller’s onboard supply outputs capable to deliver respectively 0.2 A and 1.0 A.
Entire system is supplied from the mains transformer included in the kit.

The door expander is connected with the access controller through RS485 bus.

  • access expander kit for one door
  • read-in/read-out door control
  • MCX402 IO expander
  • interface to 2 RACS CLK/DTA readers (PRT series)
  • interface to 2 Wiegand readers
  • supply output 0.2 A
  • supply output 1.0 A
  • 0.3 A battery charging current
  • deep battery discharge protection
  • tamper contact
  • space for 7 Ah battery
  • 18 V/40 VA transformer
  • metal enclosure
  • dimensions (external):
    255.0 x 255.0 x 90.0 mm (height x width x thickness)

oor expander kit for two doors. The kit consists of metal enclosure with transformer, auxiliary power supply module and IO expander.

The controlled doors can be managed on read-in side only by Wiegand or RACS CLK/DTA (PRT series readers) readers.

Door lock and readers are supplied from the controller’s on-board supply outputs capable to deliver respectively 0.2 A and 1.0 A.

The second door lock is supplied from auxiliary PS1A-LCK power supply module.
Entire system is supplied from the mains transformer included in the kit.

The door expander is connected with the access controller through RS485 bus.

  • access expander kit for two doors
  • read-in/read-out door control
  • MCX402 IO expander
  • interface to 2 RACS CLK/DTA readers (PRT series)
  • interface to 2 Wiegand readers
  • supply output 0.2 A
  • supply output 1.0 A
  • PS1A-LCK supply module for second lock
  • 0.3 A battery charging current
  • deep battery discharge protection
  • tamper contact
  • space for 7 Ah battery
  • 18 V/60 VA transformer
  • metal enclosure
  • dimensions (external):
    255.0 x 255.0 x 90.0 mm (height x width x thickness)